Running manual tests – Test-Um VALIDATOR-NT NT955 User Manual

Page 66

Advertising
background image

65

Test-Um NT955 Series

5. Running Manual Tests

Manual Tests performs individual tests on

Data, Phone, or 2-wire cables

based on defined test standards. The tests that can be performed for

each selected cable type are listed on the Manual Test screen for that

type (Figure 5.2).
5.1. Data Cables

Data Cables are defined as cables wired to T568A/B pin numbering and

pairing. Validator-NT will perform full Signal to Noise Ratio and Skew

testing as part of the cable test. Speed testing is done with the Bit Error

Rate Test (BERT). You can also send tone over the cable, check length,

flash a hub or do a Speed Test with BERT.
Note: The TP610 Remote Wiremappers are designed to report wiremap

length and Skew results only. A Link Test Error message appears

“Unable to Measure SNR.” To measure Signal to Noise Ratio you must

use the Validator Smart Remote unit.
Length Constant is used for length measurement and is adjusted in

.1pF increments by pressing the up and down arrow keys. The displayed

cable length is recalculated as the length constant is changed. This

allows an unknown length constant to be determined by attaching a

known length of cable and running the test. The length constant can

be varied up or down until the displayed length matches the measured

length. The displayed length constant is then the correct value for that

cable. This same adjustment feature is on both the Phone and 2-Wire

test screens. (Figure 5.1)

Cable Type

pF/ft.

pF/m

Data Cable

CAT3

19.0

62.5

CAT5/CAT5E/CAT6

15.0

49.0

Coaxial Cable

RG58

27.5

90.0

RG6, RG11, RG59

16.25

53.0

Security Wire

22AWG, Jacketed

24.0

78.5

22AWG, Unjacketed

14.0

46.0

20AWG, Unjacketed

16.0

52.5

18AWG, Unjacketed

17.0

55.5

Figure 5.1 Typical Cable Length Parameter