Features and benefits, World class efficiency & reliability – Trane CGWF User Manual

Page 5

Advertising
background image

5

CG-PRC012-EN

Leading in Efficiency and Reliability with State-Of-The-Art
Scroll Compressor Technology

Efficiency
The energy efficiency of the scroll chiller
results in energy costs lower than any
other comparable chiller. Full load
efficiencies are improved beyond
reciprocating chillers, but part load
efficiencies are simply unmatched by any
other manufacturer.

Superior efficiencies are obtained by
combining many of the traditional scroll
chiller energy efficient features with the
Trane scroll compressor technology.
HERE’S HOW:

• Scroll compressor’s positive

displacement design

• Dual refrigerant circuits (40-60 ton units)
• Multiple compressors
• Optimum system design
• Reduced friction
• No valves
• Advanced heat transfer surfaces

Chart illustrates low torque variation of the
Trane scroll compressor vs reciprocating
compressor.

World Class Efficiency
& Reliability

Operating Torque

Reliability
The Trane scroll chiller with many new
improvements, now brings an exciting
new compressor to the commercial
market — the Trane scroll compressor.
Trane has designed the scroll
compressor to be a leader in reliability.
HERE’S HOW:

• Simple design with 64 percent fewer

parts than equal capacity reciprocating
compressor.

• Scroll compliance allows liquid and dirt

to pass through without damaging
compressor (liquid slugging resistant).

• Advanced microelectronics protect both

compressor and motor from typical
electrical fault conditions.

• Scroll compressors have less than a

third the torque variations of a
reciprocating compressor.

• Years of laboratory testing have

optimized compressor and chiller
systems reliability.

• Water-cooled scroll chillers are factory

tested.

ASHRAE Standard 90.1 All Trane chillers
meet and exceed the new efficiency
levels mandated by ASHRAE Standard
90.1. This new standard requires higher
efficiencies than past technologies can
deliver. It mandates higher efficiency
levels for scroll water chillers in
comparison to reciprocating chillers. In
fact, energy efficiency is so paramount
the US Federal Government has
adopted standard 90.1. Federal Executive
Order mandates energy consuming
devices procured must be in the top 25%
of their class. In the case of chillers,
ASHRAE 90.1 is the product standard for
measurement.

Risk. Not only has ASHRAE 90.1 been
adopted by the US Federal Government,
it’s expected to be adopted domestically,
if not globally, in the future. Make sure
that your chillers as well as your entire
HVAC system complies, or you may be
caught retrofitting your project with new
equipment and paying extra design
dollars if the code changes during
construction.

Trane’s CGWF was designed with the
end user’s requirements in mind.
Efficiency and reliability were primary
design concerns with this latest
generation machine.

Graph illustrates Trane scroll chiller’s superior annual energy costs vs typical reciprocating
chillers.

Scroll Chiller Energy Usage Savings

Kilowatt Hours

Chiller Load (%)

Typical Reciprocating
Chiller

Scroll Chiller

10-20% Annual Energy Savings

Features and
Benefits

Advertising
This manual is related to the following products: