Networking, 1 connecting networked systems, 1 500-26 network rear connector unit (rcu) – Trilogy Touch Technology Trilogy Commander Digital Intercom 9 User Manual

Page 31: Section 4

Advertising
background image

Commander Installation Guide

Issue 9

Trilogy Communications Limited

Page 31 of 81

4. N

ETWORKING

4.1 CONNECTING NETWORKED SYSTEMS

The optional Network hardware comprises two components:

• 500-25 Network Card
• 500-26 Network Rear Connector Unit (RCU)

The RCU provides the interface to other networked Commander systems. Note that:

• Interconnection can be made by coax (BNC) or CAT5 (RJ45). It is not possible to “mix”

the interconnection methods. Having chosen the means of connection, do not fit any
other connectors.

• The coax cable connection requires two separate cables (RX and TX) for each link. The

CAT5 connection method requires only a single cable per link.

• Network connections are made on a point to point basis. Therefore, a complete system,

comprising a number of matrices, will always contain an even number of network cards.
See the diagram below which shows a three matrix LAN.

4.1.1 500-26 NETWORK REAR CONNECTOR UNIT (RCU)

To link two network systems, connect as shown on the following diagrams.

BNC -- data TX

BNC -- data RX

RJ45 – data TX/RX

RJ45 – data

TX/RX

Advertising