8.5.6 500-39-30 / 31 1U 12 KEY PANEL WITH LOUDSPEAKER

This panel provides more basic facilities than the 500-30 range. It does not have LCD
displays and only provides connection to the matrix, audio I/O and the test port at the rear.
An installation specification is given below.

Dimensions

485mm wide x 44.5mm high x 150mm deep
(excluding connectors) 200m approx. (including
mating connectors)

19” x 1RU rack mounting

Mains Input

90 – 260 V ac, 50-60Hz

Current Consumption

150mA @ 90V ac, 50mA @ 250V ac.

8.5.6.1 500-39-30 Connector Pin Out

Matrix – D9 Fixed Plug

Pin

Function

1 NC

(Screen)

2 Data

Out-

3 Data

In-

4 Audio

Out-

5 Audio

In-

6

Data Out +

7

Data In +

8

Audio Out +

9

Audio In +

Test– D9 Fixed Socket

Pin

Function

1 Analyse

Input

2

Enable Remote Boot

3 Ground
4

Transputer Link Out +

5

Transputer Link In +

6 Error

signal

Out

7 Reset

In

8

Transputer Link Out-

9

Transputer Link In-

Headset - 5 Pin XLR Fixed
Socket (front panel)

Pin

Function

1

Mic IN (Screen)

2 Mic

IN

3

Headset Gnd

4 Headset

Out

5 Headset

Out

Audio I/O – D15 Fixed Socket

Pin Function

Notes

1

Slave Mic Input

Line level, un-balanced

2

+15V Out (for slave mic panel)

NOT protected!

3

Clean Mic Out +

Line level, balanced, pair with 11

4

Ext CUT Input (for slave mic panel)

Parallel function to front panel Cut
Switch. Ground to activate

5 Chassis

Ground

6 No

connection

7

External Input to LS Amp -

Line level, balanced, pair with 14

8

Matrix Audio Input to Panel / parallel output -

Line level, balanced, pair with 15

9

Ext Mic Cut output (to slave panel)

Normally grounded. O/P is open
circuit when front panel cut selected.

10

-15V Out (for Slave mic panel)

NOT protected

11

Clean Mic Out -

Line level, balanced, pair with 3

12 Mic

Ground

13

Loudspeaker Output

8 ohm loudspeaker

14

External Input to LS Amp +

Line level, balanced, pair with 7

15

Matrix Audio Input to Panel / parallel output +

Line level, balanced, pair with 8

NB 15V supplies are also used to derive 12V for panel. (Thermally Fused @ 0.7A)

The 500-39-31 panel includes an additional expansion connector, logic GPIO signals and
footswitch connector in the same format as the 500-3x-3x series expansion panels. It is only
available to special order. See section 8.5.2.2 for connector details.