9.5 MISCELLANEOUS I/O CARD

Number of physical Inputs

28, grounding contact

Number of physical Outputs

24, earth-free opto-isolated mosfet

Loopback I/O

Outputs 29-40 internally loped back to inputs
29 to 40.

Tone Generator

3 tones generated, 315Hz, 1kHz, 1.9kHz

“Blip” Generator

3 off 450ms blips generated, triggered from
outputs 25, 26 and 27 respectively

Input Logic Monitoring

4 LEDs with card edge selector to allow any
state of inputs in blocks of 4 to be monitored

Output Logic Monitoring

4 LEDs with card edge selector to allow any
state of outputs in blocks of 4 to be
monitored

Input

Audio

Source

Monitoring

Any 1 of 384 system audio sources
monitored by card edge bar-graph display,
card edge 3.5mm headphone socket, and
rear connector output.

Remote

Control

Selectable RS232/422 and baud rate.
Remote control of logic inputs, and output
dump when logic outputs made - please ask
Trilogy Communications for further details.

9.6 P.C.

Type

Any IBM PC or compatible computer running
Windows 2000 or later We suggest a
Pentium 1GHz (or better) with a minimum
512MB of RAM.