5.6 500-43-50 12 WAY ROTARY ENCODER EXPANSION PANEL

These may only be connected to panels from the 500-xx--5x range.

Information about the following legacy panel types is also provided here:

• 500-43-51 1U, 8 REN level control panel

5.6.1 SPECIFICATION

Dimensions

485mm wide x 44.5mm high x 150mm deep
(excluding connectors) 200m approx. (including
mating connectors)

19” x 1RU rack mounting

Mains Input

90 – 260 V ac, 50-60Hz

Current Consumption

150mA @ 90V ac, 50mA @ 250V ac.

5.6.2 REAR CONNECTOR LAYOUT

The “expansion in” and “expansion out” connections are provided on RJ45 sockets. The pin-
out format of these connectors is given below.

Expansion in (Matrix) – RJ-45 fixed
socket on panel

RJ-45
Pin

Function

1

Panel Data out +

Pair
1

2

Panel Data out -

3

Panel Data In +

Pair
2

6

Panel Data In -

5

Panel Audio out +

Pair
3

4

Panel Audio out -

7

Panel Audio in +

Pair
4

8

Panel Audio in -

Cable

Screen

Expansion out (Expansion) – RJ-45
fixed socket on panel

RJ-45
Pin

Function

1

Panel Data in +

Pair
1

2

Panel Data in -

3

Panel Data out +

Pair
2

6

Panel Data out -

5

Panel Audio out +

Pair
3

4

Panel Audio out -

7

Panel Audio in +

Pair
4

8

Panel Audio in -

Cable

Screen