6.2.3 CONNECTING THE HARDWARE

The instructions below assume that the PC is currently fitted with a suitable transputer link
adaptor card and is in use for the PathFinder application.

• Close

PathFinder

• Identify the download interconnection cable.

¾ For desktop computers fitted with the Archipel link adaptor card, this will normally be

a grey coloured D37 (PC) to D9 (Commander).

¾ Disconnect the cable at both ends and replace with the violet coloured programming

lead. Connect only at the computer.

¾ For computers fitted with the Sundance SMT104 PCMCIA link adaptor, this will

normally be a multi-part cable, with a D25 Male-Female “join”. Break this join.

¾ Connect the violet D25-D9 cable instead.

• Move the “free” D9 connector to the front of the matrix. This may be connected directly

to:-

¾ 500-01-10 TDM Controller

¾ 500-02-1x Talkback Controller

¾ 500-3x-3x and 500-4x Series Control Panels

An additional D9 –Molex adaptor is required to reprogram the 500-08-10 Changeover Card.
See section 6.2.4.4.

6.2.4 COMPLETING THE REPROGRAM SEQUENCE

6.2.4.1 500-01-10 TDM Controller

Carry out all the steps detailed in Sections 6.2.2 and 6.2.3. Now ensure that everyone is
aware that the intercom system is about to go “off air”.

Connect the violet programming lead to the D9 connector on the front of the module.

Halt the system by pressing the reset switch on the TDM controller.

On the PC, click the Program button. The progress bar indicates that the Flash RAM is being
erased, then reprogrammed. A message box indicates that the procedure is complete.

If the frame is fitted with additional TDM controllers (either >96 ports or fault tolerant), then
move the D9 to the next module and repeat the process.

When all modules have been reprogrammed, switch the power off, wait 10 seconds, then
turn the power back on. Check that the system is running by observing the LED pattern on
the TDM controllers.

6.2.4.2 500-02-1x Talkback Controller

Follow the instructions in the preceding section. Always ensure that the correct hardware
type is selected in the drop down list box and the appropriate programming code is loaded.

6.2.4.3 500-3x-3x Control Panels

Control panels may be re-programmed without disruption to the matrix. Connect the violet
programming lead to the rear connector labelled "Test/Debug”. After completing the
programming sequence, re-start the panel by removing the mains power for a few seconds.
Check that the panel re-initialises correctly by observing the LCD screen, which will display
the current software version briefly. For panels without an alphanumeric display, check for
correct operation.