Toshiba B-SX6T Series User Manual

Page 122

Advertising
background image

APPENDIX 1 MESSAGES AND LEDS

ENGLISH VERSION EO1-33056

APPENDIX 1 MESSAGES AND LEDS

EA1- 2

LED Indication

No.

LCD Message

POWER

ON

LINE

ERROR

Printer Status

Restoration by

RESTART key

(Yes/No)

Acceptance of

Status Request

Reset Command

(Yes/No)

21

SYSTEM ERROR



z 

When the following abnormal operations
are performed, a system error occurs:

(a) Command fetch from an odd address
(b) Access to word data at an odd address
(c) Access to long-word data at an odd

address

(d) Access to the area of 80000000H to

FFFFFFFFH in the logic space in
user mode.

(e) An undefined instruction in an area

other than a delay slot was decoded.

(f) An undefined instruction in a delay

slot was decoded.

(g) An instruction to rewrite a delay slot

was decoded.

No No

22

100BASE LAN

INITIALIZING…



z

z 100 Base LAN Board is being initialised.

-----

-----

23

DHCP CLIENT

INITIALIZING…



z

z The DHCP client is being initialized.

*When the DHCP function is enabled.

----- -----

24

LOW BATTERY



z  The voltage of the Real Time Clock

Battery is 1.9V or less.

No Yes

25

RFID WRITE ERROR



z 

The printer did not succeed in writing data
onto an RFID tag after having retried for a
specified times.

Yes Yes

26

RFID ERROR



z  The printer cannot communicate with the

RFID module.

Yes Yes

NOTE: When an error message listed above appears on the LCD message display, please refer to Section 5

TROUBLESHOOTING for solution.