2.PRINTER SETUP

ENGLISH VERSION EO1-33056

2.12 Threshold Setting

E2-82

2.12 Threshold Setting

(Cont.)












(3) Press the

[PAUSE] key until the target sensor type is displayed.











(4) Set a threshold voltage (calculated in Sensor Adjustment Menu) by

using the

[FEED] or [RESTART] key, as shown below.

Threshold voltage = Midpoint between voltage at a print area and

voltage at a gap/black mark



















(5) After choosing a threshold voltage, press the

[PAUSE] key.


(6) To check for a proper operation, issue the pre-printed media in online.

If an error still occurs even after a manual threshold setting, change
the threshold voltage a little, and retry.



NOTE:

Pressing the [FEED] key one time
causes a –0.1V change, up to 0.0V.

Pressing the [RESTART] key one
time causes a +0.1V change, up to
+4.0V.

Black Mark Sensor

Feed Gap Sensor

[RESTART]

[FEED]

THRESHOLD<R>4.0V

THRESHOLD<R>3.9V

THRESHOLD<R>3.8V

THRESHOLD<R>0.1V

THRESHOLD<R>0.0V

Black Mark Sensor

THRESHOLD<T>4.0V

THRESHOLD<T>3.9V

THRESHOLD<T>3.8V

THRESHOLD<T>0.1V

THRESHOLD<T>0.0V

Feed Gap Sensor

[PAUSE]

<3> ADJUST SET
THRESHOLD<T>1.4V

<3>ADJUST SET

THRESHOLD<R>1.0V