2.8.1 Parameter Setting

(Cont.)




(5) Stop Bit Length Selection
This parameter is to choose a stop bit length of the RS-232C interface.
Be sure to match a setting with a host computer.
When “<2>PARAMETER SET” appears, press the

[PAUSE] key until

the following display appears.




Use the

[FEED] or [RESTART] key to select a desired option.







After selecting a stop bit length, press the

[PAUSE] key.


(6) Parity Selection
This parameter is to choose the parity of the RS-232C interface.
When “<2>PARAMETER SET” appears, press the

[PAUSE] key until

the following display appears.




Use the

[FEED] or [RESTART] key to select a desired option.








After selecting the parity, press the

[PAUSE] key.


(7) Flow Control Code Selection
This parameter is to choose a flow control code of the RS-232C interface.

When “<2>PARAMETER SET” appears, press the

[PAUSE] key until

the following display appears.




Use the

[FEED] or [RESTART] key to select a desired option.








After selecting a flow control code, press the

[PAUSE] key.

STOP BIT 1bit

STOP BIT 2bits

<2>PARAMETER SET
STOP BIT 1bit

[RESTART]

[FEED]

<2>PARAMETER SET
XON+READY AUTO

[RESTART]

[FEED]

XON+READY AUTO

XON/XOFF AUTO

READY/BUSY

XON/XOFF

READY/BUSY RTS

XON/XOFF mode

XON/XOFF+READY/BUSY

(DTR) mode

READY/BUSY (DTR)

mode

XON/XOFF mode

RTS mode

<2>PARAMETER SET
PARITY NONE

PARITY EVEN

PARITY ODD

[RESTART]

[FEED]

PARITY NONE

NOTE:

The following is the detailed
descriptions for each transmission
control code.
1) XON/XOFF AUTO

At the power on time, the printer
outputs XON. At the power off
time, the printer outputs XOFF.

2) XON+READY AUTO

At the power on time, the printer
outputs XON. At the power off
time, the printer outputs XOFF.

3) READY/BUSY

At the power on time, the DTR
signal output from the printer
turns to High level (READY). At
the power off time, the printer does
not output XOFF.

4) ON/XOFF

At the power on time, the printer
outputs XON. At the power off
time, the printer does not output
XOFF.

5) READY/BUSY RTS

At the power on time, the RTS
signal output from the printer
turns to High level (READY). At
the power off time, the printer does
not output XOFF.

NOTES:

1. When using the hardware flow

control, the control signals and
data must be in pairs between the
printer and the PC.
Printer Host
TD

RD

RD

TD

RTS

CTS

CTS

RTS

DSR

DTR

DTR

DSR

Refer to the RS-232C connector’s
pin layout in APPENDIX 2.
Check if the printer and the PC is
properly connectable with your
cable

2. Be careful that there are two

types of RS-232C cable; straight
cable and cross cable.
Use a straight cable for this
printer.