Connections, Control i/o terminal connections, Remote volumes 1, 2 – TOA Electronics M-9000 User Manual

Page 53: Control inputs 1 – 4, Control outputs 1 – 4, P. 53

Advertising
background image

53

14.1. Control I/O Terminal Connections

14.1.1. Remote volumes 1, 2

Volume of the input or output channels can be remotely adjusted. (The REMT VOL 1 terminal is factory-preset
to output 1, and the REMT VOL 2 to output 2.)
Connect a 10 k

Ω (linear taper) variable resistor as shown below or input the DC voltage of 0 to +10 V.

The larger the variable resistor resistance, the larger the volume.

14.1.2. Control inputs 1 – 4

Connect switch contacts, etc. to these terminals.
Open voltage is 3.3 V, and the short-circuit current is 1 mA or less.

14.1.3. Control outputs 1 – 4

Use these terminals to activate LEDs, relays, and other external equipment.
Maximum operating current is 50 mA, and the maximum applicable voltage is +27 V.

REMT VOL1

(Remote volume 1)

REMT VOL2

(Remote volume 2)

IN

(Control inputs)

OUT

(Control outputs)

IN

E

IN

E

1

2

3

4

E

1

2

3

4

E

DC voltage
0 to 10 V

Applicable DC voltage
Max. 27 V DC

LEDs, Relays, etc. (Max. 50 mA)

or

Voltage control
10 k

Ω (linear-taper)

Contact closures,
Open collectors, etc.
(Open voltage: 3.3 V, Max. 1 mA)

E

E

4

4

3

3

1
2

2

1

VOL2

REMT

VOL1

REMT

OUT

IN

I/O

CTRL

E

IN

E

IN

Control-I/O connection terminal

14. CONNECTIONS

Advertising