Configuring the Output

Qualified service personnel can change the output configuration with
the following procedure:

CAUTION. The 764 contains static-sensitive components. The
following procedure should be performed by qualified technicians
only.

1. Disconnect power and all other connections from the 764 rear

panel and then remove the instrument from its enclosure. The
Analog Line Output circuit board assembly is mounted
horizontally above the audio XLR connectors at the rear of the
chassis. The configuration jumper pins are readily accessible on
the top surface of the board.

2. Identify the jumper configuration in Table 32 that corresponds to

the desired output; add and remove jumpers to/from the jumper
pin pairs to achieve that configuration. Pin pairs J20, J21, J22,
and J23 are provided as a convenient place to “park” unused
jumpers. If you need additional jumpers for the new configura-
tion, take them from J20–J23; if you have extra jumpers after
reconfiguration, put them onto J20–J23.

Table 32: Output configuration jumper locations

Output

Jumper configuration

AES connector*

Fixed, +24 dBm

J914

Variable, to +24 dBm

J913

Variable, to 2.0 V

RMS

J913

*

See configuration procedure step 3.