Tektronix 070-8811-08 User Manual

Page 47

Advertising
background image

Operating Basics

32

764 Digital Audio Monitor User Manual

SYNC ERR flags as shown in Figure 24. Please see the following
paragraphs for more information.

Figure 24: The SYNC ERR Flags

H Frame Synchronization Error — for each input with respect to the

Digital Audio Reference (DAR), when one is present at the
REFERENCE input. Otherwise — when both inputs are active but
no DAR is present — the error of input 3–4 relative to input 1–2,
as depicted in Figure 25. Errors are expressed as the percentage
of a complete digital audio frame.

Notice the “No Reference Signal” message in Figure 25. It will
appear whenever a DAR is absent from the REFERENCE input.

Figure 25: Sync Error Reporting in the Absence of a DAR

The AES11 standard specifies that synchronization errors should
be no greater than 25% of the audio sample frame. When the
synchronization error exceeds this limit, a SYNC ERR flag

Advertising