Tektronix 070-8811-08 User Manual

Page 113

Advertising
background image

Appendix C: Options

98

764 Digital Audio Monitor User Manual

Pin 3 (–)

Pin 2 (+)

Pin 1 (shield)

Analog line output XLR

(+)

Gnd

Receiving equipment

unbalanced input

Pin 3 (–)

Pin 2 (+)

Pin 1 (shield)

(+)

Gnd

OR

Figure 40: Connecting to an unbalanced input

NOTE. Connecting a line to ground as shown in Figure 40 forces the
analog outputs into unbalanced mode. The outputs will clip above
approximately +20 dBu in unbalanced mode.
Do not use unbalanced
mode when you have configured the instrument for either fixed high
level output or variable high level output.

Advertising