USB HID Keyboard Emulation Swipe Reader

10

MSR (Non-Keyboard Emulation Version). Please refer to Technical Manual 99875320 for
further information regarding the USB IntelliHead HID reader.

The device’s programmable configuration options affect the format of the card data.

The card data format for the default configuration is as follows:

[Tk1 SS] [Tk1 Data] [ES] [Tk2 SS] [Tk2 Data] [ES] [Tk3 SS] [Tk3 Data] [ES] [CR]


where:
Tk1 SS

=

% (7-bit start sentinel)

Tk2 SS

=

; (ISO/ABA 5-bit start sentinel)

@ (7-bit start sentinel)

Tk3 SS

=

+ (ISO/ABA start sentinel)

# (AAMVA start sentinel)

& (7-bit start sentinel)

ES =

?

(end

sentinel)

CR

=

(carriage return) (0D hex)


All data will be sent in upper case regardless of the state of the caps lock key on the keyboard. If
no data is detected on a track then nothing will be transmitted for that track. If an error is
detected on a track the ASCII character E will be sent in place of the track data to indicate an
error.

The card data format for all programmable configuration options is as follows:

[P11] [P13] [Tk1 SS] [Tk1 Data] [ES] [LRC] [P14] [P5] [P13] [Tk2 SS] [Tk2 Data] [ES]
[LRC] [P14] [P5] [P13] [Tk3 SS] [Tk3 Data] [ES] [LRC] [P14] [P5] [P12]


where:

ES =

?

(end

sentinel)

LRC =

Longitudinal

redundancy

check

character

P5 =

Terminating

character

P11 =

Pre

card

character

P12 =

Post

card

character

P13 =

Pre

track

character

P14 =

Post

track

character

Tk1 SS

=

% (7-bit start sentinel)

Tk2 SS

=

; (ISO/ABA 5-bit start sentinel)

P6 (7-bit start sentinel)

Tk3 SS

=

P8 (ISO/ABA start sentinel)

P9 (AAMVA start sentinel)

P10 (7-bit start sentinel)


All fields with the format P# are programmable configuration property numbers. They are
described in detail later in this document.