10

SOFTWARE COMMANDS

Logic Controls pole displays are controlled by command codes and

data from the computer. The model of pole display that you have will

determine which command set works with your pole. Refer to the

model identification chart for further information.

Commands are transmitted to the pole display as ASCII codes. The

command codes listed below are expressed in hexadecimal (base 16)

numbers enclosed inside angle brackets < >, in decimal numbers

enclosed in parenthesis ( ), and in ASCII characters enclosed in curly

brackets { }. Do not include the brackets as part of the command. ‘ ^ ‘

character denotes ‘Ctrl’ in the keyboard. Press and hold ‘Ctrl’, then

press the next key.

LOGIC CONTROLS COMMAND SET (LD9000, LD9000-X):

1. Vertical Scroll Mode <12>, (18), {^R}:

Data is written into the second row and transferred to the first row

when carriage return is received, leaving the second row empty.

2. Normal Display Mode <11>, (17), {^Q}:

Data can be written into either row. Moves to the left most digit of

the other row when line is full.

3. Brightness Control <04>, (04), {^D}:

The brightness of the display can be adjusted using this

command followed by a data byte <FF>, <60>, <40> or <20>.

4. Back Space <08>, (08), {^H}:

The cursor position moves one digit to the left erasing the

previous information.

5. Horizontal Tab <09>, (09), {^I}:

The cursor position shifts one digit to the right without erasing

character at original cursor position.

6. Line Feed <0A>, (10), {^J}:

The cursor position moves to the same position in the other row.

In vertical scroll mode, if cursor was in second row, the cursor will

not move and display will scroll up.