USB HID Keyboard Emulation Swipe Reader

18

TRACK_DATA_SEND_FLAGS PROPERTY

Property ID:

4

Property Type:

Byte

Length: 1

byte

Get Property:

Yes

Set Property:

Yes

Default Value:

63 (hex)

Description:

This property is defined as follows:

0

SS ES LRC 0 LC Er Er

SS

0 – Don’t send Start Sentinel for each track

1 – Send Start Sentinel for each track

ES

0 – Don’t send End Sentinel for each track

1 – Send End Sentinel for each track

LRC 0 – Don’t send LRC for each track

1 – Send LRC for each track

Note that the LRC is the unmodified LRC from the track data. To verify the LRC
the track data needs to be converted back from ASCII to card data format and the
start sentinels that were modified to indicate the card encode type need to be
converted back to their original values.

LC

0 – Send card data as upper case

1 – Send card data as lower case

Note that the state of the Caps Lock key on the host keyboard has no affect on
what case the card data is transmitted in.

Er

00 – Don’t send any card data if error

01 – Don’t send track data if error

11 – Send ‘E’ for each track error


This property is stored in non-volatile EEPROM memory so it will not change when the unit is
power cycled. When this property is changed, the unit must be power cycled to have these
changes take effect. If a value other than the default value is desired, it can be set by the factory
upon request.