TANDBERG F1 D13642.01 User Manual

Page 138

Advertising
background image

TANDBERG 1500 MXP

134

Pin-4

RXD (in)

Pin-3

TXD (out)

Pin-2

Presence (+12V in
daisy chain)

Pin-1

GND



Ethernet:

To connect the system to a LAN, use the Ethernet cable provided by TANDBERG (or a
standard Ethernet cable). If no LAN is available and the codec is connected directly to a
computer, use a crossover cable.

The crossover cable specification is:


If such a connection is needed, the system and the PC must use

static

TCP/IP settings

because no DHCP server is controlling the small

LAN

, which has been created between the

computer and the system. When configuring a back-to-back connection between the PC and
the system, make sure both static IP addresses exist on the same subnet.

BRI ISDN Interface:

To connect the system to BRI, use the ISDN cable provided by TANDBERG (or a standard
BRI cable).

The pinout of the S/T interface is:

PRI

Pinout

Pin-3

TX+

Pin-4

RX+

Pin-5

RX-

Pin-6

TX-



PRI ISDN Interface:

To connect the system to PRI, use the ISDN cable provided by TANDBERG (or a standard
PRI cable).

The pinout of the E1/T1 interface is:

PRI

Pinout

Crossover
PRI cable

Pin-1

TIP RX

4

Pin-2

RING
RX

5

Pin-4

RING
TX

1

Pin-5

TIP TX

2


Note! TANDBERG recommends always using category 5 cabling.