Parallel logic input circuit, Output characteristics open collector to ground – Telos NX12 User Manual

Page 33

Advertising
background image

InsTallaTIon | 23

PiN

DESCRiPTiON

5

Record Start 1

6

Ring Mute In 1

7

N/C

8

+5VDC (50mA max)

9

Record Stop 1

10

User Out (Dump) 2

11

Ringing Out 2

12

Priority Ringing Out 2

13

Ring Mute In 2

14

(reserved)

15

N/C

p

a

r

a

l

l

e

l

C

o

n

T

r

o

l

1

8

Note for the Curious

The DB- designation for D-Sub connectors is from Cinch Corp’s part numbering system. The
proper Cinch designation for a 15 pin D-Sub connector is a DA-15p (plug) or DA-15s (socket)
not DB-15! (Our thanks to Mike Schweizer, for contributing this tidbit.)

Input Characteristics

The NX12’s inputs are designed to be universal. They accept either a voltage source up

to 24VDC, or a closure to ground, which may be provided by switches, relays, or logic

outputs. In the latter case either ‘totem-pole’ or open-collector will work. The inputs are

active low.
A built in 1k Ohm pull up resistor is provided.

Parallel logic input circuit:

3 0 v m a x

+5V

Output Characteristics

Open collector to ground.

These will require a pull-up resistor to drive TTL-style logic inputs. Most equipment has

the pull-up built into the input, but if there is no pull-up, you’ll have to add one, connect-

Advertising