Tesla TI2000GPU-24 User Manual

Page 12

Advertising
background image

3-1

3-4. 120-240 VAC CHARGER AND AC TO DC CONVERTER LIMITS

The unit is designed with a single point AC receptacle for external

power to operate both the internal charger and converter. The units

AC voltage range can be factory set from 105 to 250 VAC at 50 to 60

Hz depending upon customer requirements. The AC power cord provided

with the unit is the mechanism that ensures the specified AC power

source is properly supplied to the unit (see paragraph 3-5).Use no

others

INTERNAL CHARGER: NO LIMIT AC power cord can remain connected

when power cells are fully charged. When the power cells are fully

charged the unit’s intelligent charger will go to a stand-by mode,

monitor the power cells state of charge, and only charge the power

cells to ensure they stay at maximum capacity.

INTERNAL AC TO DC CONVERTER: LIMITED (see paragraph 3-6, 3-8 and

3-10). AC power cord does not have to be disconnected when con-

verter power output is no longer required. Once DC power demand

is terminated the unit’s intelligent charger will remain on line to

ensure power cells are charged to maximum capacity.

CAUTION

Unit will be damaged if unapproved AC power is applied.

3-5 AC POWER CORD LIMITS

The AC power cord governs which AC power source the unit is set to

operate from. The Turbo Start 2000 is supplied with a single cus-

tomer specified AC power cord. Some customers may specify a univer-

sal AC option (for worldwide mobility), which comes with two (2)

power cords, one for 120 VAC 60 Hz and the other for 240 VAC 50 Hz

(SEE APPENDIX A). Each power cord is marked accordingly. Below are

the following three (3) types of AC power cords available and their

limits.

120 VAC 60 Hz power cord (USA): LIMITED TO 105-125 VAC 60 Hz power

source only.

120 VAC 60 Hz power cord (Universal): LIMITED TO 105 VAC to 250 VAC

50/60 Hz power source using proper cord set.

240 VAC 50 Hz power cord (European): LIMITED TO 210-250 VAC 50-60 Hz

power source only.

FOR MORE INFORMATION ON POWER CORDS SEE APPENDIX A