background image

that cooling fan is functioning.

4-2

CAUTION

REMEMBER,when the AC line cord is plugged in, the unit must be placed

in the horizontal position to allow the cooling fan to operate prop-

erly!

Unit may overheat if cooling fan fails. Do not operate if cooling

fan fails.(More than one green bar present on bar graph)

3. CHECK DC POWER CABLE/CONNECTORS FOR DAMAGE - Check cable for

cuts, chafing or evidence of being crushed. Check connectors for

cracks, cuts, distortions, excessive wear, broken/loose fasteners or

loose cable attachment.

4-6. 24 VDC GROUND POWER (NO 120 OR 240 VAC POWER SUPPLY) ENGINE

STARTING OR DC SYSTEM POWER

1. TRANSPORT UNIT - The Turbo Start 2000 is easily transported using

the wheels that are incorparated into the unit. The AXEL EXTENTION

kit (included with the unit) ensures that the Turbo Start 2000 is

stable. The unit is engineered to be pushed rather than pulled.

2. CONNECT DC POWER CABLE TO UNIT - Ensure power cable connector is

fully seated into unit’s connector. Set

the unit down horizontally

ensuring vent ports are un-blocked.

3. CONNECT DC POWER CABLE TO AIRCRAFT - Ensure ground power

cable connector is fully seated into aircraft ground power recep-

tacle. DC bus power should come on and aircraft volt meter should

indicate 24 VDC to 23.5 VDC (23 VDC minimum).

4. ENGINE STARTING - Check power cable for security and correct

installation prior to engine start. Follow ground power engine

Advertising