Storage range:

-60C

o

(-76

o

F) TO +60C

o

(+140

o

F)

(C0NTINUED ON NEXT PAGE)

3-4

CAUTION

Unit may be damaged if operated when unit’s cold or heat soaked tempera-

ture exceed the specified limit. If unit is operated when cold or heat

soaked temperature limit is exceeded, a full functional check should be

accomplished prior to continued use.

NOTE

If unit should overheat, an over-temperature sensor will shut down 120-

240 VAC functions (charger and converter) until unit cools to normal

operating temperatures.

3-11. ENVIRONMENTAL

Operating any electrical equipment in the presence of moisture cre-

ates possible safety hazards and/or potential for equipment damage.

Every effort has been made, within the scope of existing technology

to prevent foreseeable safety hazards and make the Turbo Start 2000

moisture resistant to prevent damage or failure. If the Turbo Start

3000 is exposed to moisture, preventive measures and precautions

shall be taken to:

a.

prevent accumulation of moisture on AC and DC con-

nectors/receptacles

b.

minimize moisture entering FWD inlet and AFT out-

let cooling fan vent ports

The limits and operational constraints listed below shall apply for

the following environmental (weather) conditions:

Heavy or steady rain:

OPERATION NOT RECOMMENDED

Light rain, drizzle:

NO CONVERTER OR CHARGER 120-240 VAC

fog, snow or sleet:

POWER SHALL BE APPLIED.

Unit inlet and outlet vent ports shall be covered from exposure.

Unit shall be kept horizontal.