Codabar a/t, b/n, c/*, d/e (9, 10, 11, 12), Upc-a (style 13) – Tally Genicom Matrix Printer User Manual

Page 56

Advertising
background image

7265 Programmer’s Manual

52

Copyright © 2004 TallyGenicom Chapter 3 ANSI Bar Codes

Codabar A/t, B/n, C/*, D/e (9, 10, 11, 12)

1

Bars per character: 4 dark bars and 3 light bars

2

Character set: 0 through 9 and the four additional characters :/ . +

3

Start/Stop characters: Yes (A,B,C,D/A,B,C,D,T,N,*,E)

4

Center character code: None

5

NULL character: Yes

6 Intercharacter gap: None

7

Characters per symbol: Variable

8

Check digit: If needed, it must be generated by the data source

9

Delimiters: Space, comma, horizontal tab, hp_relative

10

HR characters: Currently selected font, special HR font, special OCR-A/OCR-B
font (120 DPI only)

11

CPI at default element widths: 5.05

12

Combined start-stop character length: 0.458"

UPC-A (Style 13)

1

Bars per character: 2 dark bars and 2 light bars

2

Character set: 0 through 9

3

Start/Stop characters: 2 dark bars and 1 light bar

4

Center character code: Yes

5

NULL character: Yes

6

Intercharacter gap: None

7

Characters per symbol: 12

8 Check digit: The check digit can

be supplied by the data source

9

Delimiters: Space, comma, horizontal tab, hp_relative

10

HR characters: Currently selected font, special HR

11

CPI at default element widths: 7.64