Administrator Settings

227

Gatekeeper Settings


Gatekeeper Discovery

Auto

The system will automatically try to register to any available gatekeeper. If a
gatekeeper responds to the request sent from the codec within 30 seconds this
specific gatekeeper will be used. This requires auto discovery on the gatekeeper
as well. If no gatekeeper responds, the system will not use a gatekeeper for
making H.323 calls and hence an IP-address must be specified manually.

Manual

The system will use a specific gatekeeper identified by Gatekeeper IP-address.


Gatekeeper IP Address

This is the gatekeeper IP-address that is used if you specify H.323 Call Setup: Gatekeeper and
Gatekeeper Discovery: Manual.


Note that if your system is part of a TANDBERG Expressway™ firewall traversal solution and
is placed outside the firewall, you should register the IP address of your Border Controller as
the Gatekeeper IP address and set H.323 Call Setup to Gatekeeper.


Authentication Mode

Auto

If Authentication Mode is set to Auto and the gatekeeper indicates that it requires
authentication, the endpoint will automatically try to authenticate itself to the
Gatekeeper.

Off

If Authentication Mode is set to Off the system will not try to authenticate itself to a
Gatekeeper, but will still try a normal registration.


Authentication ID / Authentication Password

The system sends the Authentication ID and Password to a Gatekeeper for authentication. The
authentication is a one way authentication from the endpoint system to a Gatekeeper, i.e. the
endpoint is authenticated to the Gatekeeper. If the Gatekeeper indicates that no authentication is
required, the endpoint will still try to register.

Multiple H323 Aliases

On

If set to On, the system will register multiple H.323-IDs on the Gatekeeper based on
the values of the parameters: System Name, International Name and H.323 ID.
Up to 3 aliases are possible.

Off

If all fields are empty, the System Name is set to TANDBERG-<serial no> and