TANDBERG Maestro MXP User Manual

Page 322

Advertising
background image

TANDBERG Maestro MXP

322

Cable Specification
RS-449 Cable to KIV-7
TANDBERG MXP and Classic Endpoints that support External
Network


• Connector on Tandberg End:

o

Female 26pin High Density DSUB Newark P/N 50F2055 or Equivalent

• Connector on RS-449:

o

DSUB 37 pin Male

Signal Name

Female

26pin DSUB

(Tandberg end)

Pin Number

Male

37pin DSUB

(DCE end)

Pin Number

Comments

Frame Ground

1

1

Do not connect shield to FGND

Send Data (A)
Send Data (B)

11
12

4

14

Twisted Pair

Send Timing (A)
Send Timing (B)

17
18

15
12

Twisted Pair

Receive Data (A)
Receive Data (B)

13
14

3

16

Twisted Pair

Receive Timing(A)
Receive Timing (B)

15
16

17

9

Twisted Pair

LOS

25

31

Signal Ground

19

1

4,20,28

19,23,27

Jumpers
Jumpers




Advertising