Models 340, 341, 342

Operating Procedures

071017

Step 10

Lay the hopper gasket and feed tube in the bottom of

the mix hopper.

Figure 19

Step 11

(Optional Rack Assembly)
Complete the assembly by inserting the flavor bottles

into the rack assembly on the front of the machine.

Figure 20

Sanitizing

Step 1

Prepare two gallons (7.6 liters) of an approved 100

PPM chlorine based sanitizing solution (Examples:

Stera--SheenR or Kay-5R). USE WARM WATER

AND FOLLOW THE MANUFACTURER’S SPECIFI-

CATIONS.

Step 2

Pour the two gallons (7.6 liters) of sanitizing solution

into the hopper and allow it to flow into the freezing

cylinder.

Figure 21

Step 3

While the solution is flowing into the freezing cylinder,

brush clean the mix hopper, mix inlet hole, air tube and

mix level sensing probe.

Figure 22

Step 4

Place the control switch in the “WASH” position. This

will cause the sanitizing solution in the freezing

cylinder to agitate. Allow the solution to agitate for five

minutes.

Figure 23