21

Models 340, 341, 342

Important: Operator Checklist

Winter Storage

If the place of business is to be closed during the winter

months, it is important to protect the freezer by

following certain precautions, particularly if the

building is subject to freezing conditions.
Disconnect the freezer from the main power source to

prevent possible electrical damage.
On water cooled freezers, disconnect the water

supply. Relieve pressure on the spring in the water

valve. Use air pressure on the outlet side to blow out

any water remaining in the condenser, and then add a

liberal amount of permanent type auto anti-freeze.

This is extremely important. Failure to follow this

procedure may cause severe and costly damage to the

refrigeration system.

Your local Taylor Distributor can perform this service

for you.

Wrap detachable parts of the freezer such as beater,

blades, drive shaft, and freezer door, and place in a

protected dry place. Rubber trim parts and gaskets

can

be protected

by

wrapping

them

with

moisture-proof paper. All parts should be thoroughly

cleaned of dried mix or lubrication which attract mice

and other vermin.