Draining product from the freezing cylinder, Rinsing – Taylor 342 User Manual

Page 21

Advertising
background image

17

Models 340, 341, 342

Operating Procedures

Draining Product From the

Freezing Cylinder

Step 1

Place the control switch in the “OFF” position as far

ahead of cleaning time as possible to allow frozen

product to soften for easier cleaning.

Figure 31

Step 2

Remove the hopper cover, gasket, and air tube and

take these parts to the sink for cleaning.

Figure 32

Step 3

With a sanitized pail under the door spout, place the

control switch in the “WASH” position and move the

draw handle to the right. When all the product stops

flowing from the door spout, move the draw handle to

the left and place the control switch in the “OFF”

position. If local health codes permit, empty the rerun

into the rerun can. Cover the container and place it in

the walk-in cooler.

Figure 33

ALWAYS FOLLOW LOCAL HEALTH CODES.

Rinsing

Step 1

Pour two gallons (7.6 liters) of cool, clean water into

the mix hopper. With the brushes provided, scrub the

mix hopper, mix inlet hole, and mix level sensing

probe.

Figure 34

Step 2

With a mix pail beneath the door spout, place the

control switch in the “WASH” position and move the

draw handle to the right. Drain all the rinse water from

the freezing cylinder. When the rinse water stops

flowing from the door spout, move the draw handle to

the left and place the control switch in the “OFF”

position.

Repeat this procedure until the rinse water being

drawn from the freezing cylinder is clear.

Advertising
This manual is related to the following products:

341, 340