Tannoy ACTIVE STUDIO MONITORS User Manual

Page 31

Advertising
background image

31

Parameter Categories

Global Parameters
These parameters apply to the entire system: -

Global parameters stored with presets

Bass Management

Mute Status

Global parameters NOT stored with presets

Ref. Levels

Analog Input Sensitivity

Selected Setup

BNC Sync

Local Parameters
These parameters apply to individual Precision monitors: -

Local parameters stored with presets

X-Curve

Parametric EQ setting (set via optional PC-iP

)

LFE Gain (subs)

LFE Low Pass (subs)

Rel. Level

Local parameters NOT stored with presets

Bass and Treble

Delay

Lock status (set via optional PC-iP

)

Room position

Calibration Level

Tasks

Phase (Subs)

Polarity (Subs)

Recall

Press ENTER and use ARROW keys to select presets

Press ENTER to recall/load the selected preset

If no user-preset are stored on locations 1 to 4, presets 16 to 19 are loaded instead.
Complete preset list is available on page 52.

Store

Press ENTER and select storage location using the ARROW keys

Press ENTER again to store.

Storage location can be 1-15.
Parameter can be locked via the optional PC-iP

Installers software. When trying to change values on a locked parameter

the LCD display reads “Locked”.