15 - ENGLISH

hand. The door is now ready for being
disassembled.

6. Dismantle the door into pieces:
• Unscrew the handle adjusting knob.

• Remove the guide and the spring.

• Remove the delivery door.

• Remove the O-rings.
7. Pull the agitator and the stuffing box out: remove

the scraping pads and wash them thoroughly. Use
the cleaning rod to clean the pads seats on the
agitator.

8. Wash all components with a detergent/sanitiser

solution. Let them dry in the open air.

9. Accurately sanitise the cooling cylinder.
10. Remove the drip drawer from the front panel and

thoroughly wash it. If the drip drawer contains
some mxture, the agitator stuffing box is leaking
and shall be replaced.

11. Lubricate the OR rings and the stuffing box. Once

a week, it is advisable to rotate the agitator stuffing
box so that the rubber elasticity can be recovered.

- To preserve plastic components and gaskets,

never use solvents and/or diluents during washing.

- Sanitizing chemicals shall be used according to

laws in force and with the utmost caution.

- After any sanitizing operation, it is indispensable

not to touch the sterilized parts either with hands
or with towels, sponges or other.

- Avoid making the agitator run empty, as the

machine can be damaged.