VLYNQ Port Registers

Table 9. Status Register (STAT) Field Descriptions (continued)

Bit

Field

Value

Description

8

RERROR

Remote Error. Write a 1 to this bit to clear it.

0

No error

This bit indicates that a downstream VLYNQ module has detected a packet error. This bit is

1

set when an error indication, /E/, is received from the serial interface. See

Appendix A

.

If this bit is set, and the INTENABLE (bit 13 in VLYNQ control register) is also set, it asserts
the VLYNQ interrupt (VLQINT).

7

LERROR

Local error. Write a 1 to this bit to clear it.

0

No error.

This bit indicates that an inbound packet contains an error that is detected by the local

1

VLYNQ module.

If this bit is set, and the INTENABLE (bit 13 in VLYNQ control register) is also set, it asserts
the VLYNQ interrupt (VLQINT).

6

NFEMPTY3

FIFO 3 is not empty.

0

Indicates that the slave command FIFO is empty.

1

Indicates that the slave command FIFO is not empty.

5

NFEMPTY2

FIFO 2 is not empty.

0

Indicates that the slave data FIFO is empty.

1

Indicates that the slave data FIFO is not empty.

4

NFEMPTY1

FIFO 1 is not empty.

0

Indicates that the master command FIFO is empty.

1

Indicates that the master command FIFO is not empty.

3

NFEMPTY0

FIFO 0 is not empty.

0

Indicates that the master data FIFO is empty.

1

Indicates that the master data FIFO is not empty.

2

SPEND

Pending slave request.

0

No pending slave requests.

Indicates detection of a transfer request initiated by the VLYNQ module to the off-chip

1

peripheral (TX slave configuration bus interface).

1

MPEND

Pending master requests.

0

No pending master requests.

Indicates detection of a transfer request initiated by an off-chip peripheral to the VLYNQ

1

module (RX master configuration bus interface).

0

LINK

Link

0

Indicates that the serial interface initialization sequence has not yet completed or the link
has timed out.

1

Indicates that the serial interface initialization sequence has completed successfully.