Electrical operating condition – Unibrain 780 User Manual

Page 11

Advertising
background image

Unibrain Fire-i 580/780/785/980 Operation Manual

Page 5

1.4.

Electrical Operating Condition

The cameras feature a photo coupler as below:

Trigger

Parameter

Min

Typical

Max

I

7 mA

10 mA

20 mA

Ri

-

270 Ω

-

Vd

-

1.08 V

-

Rising trigger delay

2.24 us

3.34 us

3.36 us

Falling trigger delay

2.62 us

3.61 us

3.64 us

Strobe

Strobe Power

Strobe falling delay

Strobe rising delay

5 V

26.8 us

2.16 us

12 V

7.6 us

2.8 us

24 V

3.6 us

3.4 us