3.15. Optical Filter Control

Optical Filter control allow user to change the optical filter of the camera lens function. You can change the Bayer

patterns by moving the starting position which to output pixel data by one position up, down, right or left. (Only for

color models)

Inquiry Register

Address

Name

Field

Bit

Description

58Ch

OPTICAL_FILTER_I

NQ

Presence_Inq

[0]

Presence of this feature

Abs_Control_Inq

[1]

Capability of control with absolute value

-

[2]

Reserved

One_Push_Inq

[3]

One push auto mode (Controlled

automatically by camera only once)

ReadOut_Inq

[4]

Capability of reading the value of this

feature

On/OFF_Inq

[5]

Capability of switching this feature ON and

OFF

Auto_Inq

[6]

Auto Mode (Controlled automatically by

camera)

Manual_Inq

[7]

Manual Mode (Controlled by user)

Min_Value

[8..19]

Minimum value for this feature control

Max_Value

[20..31]

Maximum value for this feature control

Status Control Register

Address

Name

Field

Bit

Description

88Ch

OPTICAL_FILTER

Presence_Inq

[0]

Presence of this feature

0:N/A 1:Available

Abs_Control

[1]

Absolute value control

0: Control with value in Value field

1: Control with value in Absolute value

CSR if this bit =1, value in Value filed is

ignored

-

[2..5]

Reserved

On/OFF

[6]

Write : ON or OFF this feature

Read : read a status

0: OFF, 1:ON

If this bit=0, other fields will be read only.

-

[7..19]

Reserved

Value

[20..31]

Minimum value for this feature control