Strobe delay / duration table – Unibrain 780 User Manual

Page 44

Advertising
background image

Unibrain Fire-i 580/780/785/980 Operation Manual

Page 38

3.14.1. Strobe Delay / Duration Table

The table shows the strobe index by increment step through the strobe delay time and the strobe duration time. The

Increment Step is different according to strobe index.

Strobe Delay Table

Strobe Index(Y)

Increment Step

Strobe Delay Time : T

Delay Time

Range

0

1us

0us

0us

1

1us

1us

2

2us

2us

3~250

T=Y us

3us~250us

251~3900

T=Y us

251us~3900us

Strobe Duration Table

Strobe Index(Y)

Increment Step

Strobe Duration Time : T

Duration Time

Range

0

N.A

N.A

N.A

1

N.A

N.A

N.A

2

1us

2us

2us

3~250

1us

T=Y us

3us~250us

251~489

250us

T=(Y-250)*250us+250us

500us~60ms

Delay Index(Y)

Strobe Delay Time

Duration Index (Y)

Strobe Duration Time

0

0us

0

N.A

1

1us

1

N.A

2

2us

2

2us

10

10us

10

10us

100

100us

100

100us

200

200us

250

250us

300

300us

253

1ms

500

500us

257

2ms

800

800us

269

5ms

1000

1000us

289

10ms

2000

2000us

329

20ms

3000

3000us

449

50ms

3900

3900us

489

60ms

Advertising
This manual is related to the following products:

580, 785, 980