3. Locate the compression fitting and ferrule packed with

the unit. Slide the compression fitting and ferrule over
the 1/4-inch OD water supply line. Do not use thread
sealing compound or tape. Using two wrenches,
tighten the compression fitting on the supply line (see
Figure 21).

4. Carefully bend the water supply line into position and

connect the line to the solenoid valve (see Figure 22).
Avoid kinking the water supply line.

IMPORTANT

Route the water supply line through the unit so it does not
come into contact with any internal components other
than the solenoid valve. See Figure 23. Normal operation
creates some vibration. A water supply line contacting an
internal component or cabinet wall can cause excessive
noise during operation or damage to the line.

5. For recessed installations, allow extra water supply line

length to provide slack for easy removal from the
recessed area (see Figure 23). This will also safeguard
against kinking the line.

6. Go on to 7 Prepare Power Supply.

Electrical Specifications

CAUTION

Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.

The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current).
An individual, properly grounded branch circuit or circuit
breaker is recommended. GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be
sure to consult your local codes.

It is recommended to locate the receptacle behind an
adjacent cabinet (see Figure 24). Plugging the unit into a
receptacle located behind an adjacent cabinet will allow
the unit to be serviced more easily without disturbing the
installation.

Note: If receptacle is located behind the unit, additional
space will be required to make unit flush with adjacent
cabinets.

WARNING

SHOCK HAZARD — Electrical Grounding Required.

• Never remove the round grounding prong from

the plug and never use a two-prong grounding
adapter.

• Never use an extension cord to connect power to

the unit.

Go on to 8 Level the Unit.