Marine series, Installation troubleshooting, Initial start-up – U-Line SS1095FC User Manual

Page 13

Advertising
background image

09/2008

13

www.U-LineService.com

SS1095

MARINE SERIES

Installation Troubleshooting

Problem

Q:

Water is leaking under the unit.

Solution

A:

A water leak under the unit is most likely caused by a bad
connection in the water supply line. Make sure the water
line’s brass fitting is screwed tight to its valve and
threaded correctly. Make sure that plumbers tape was
NOT used; if it was remove all traces before reinstalling.

Initial Start-Up

The on/off switch is located behind the front grille. A
small opening in the top of the grille is provided to access
the switch. Ensure that the switch is turned on.

No setting adjustments should be necessary at this time.
For information about Adjusting the Temperature
Control, see the User Manual.

As soon as the ice maker
mold reaches the proper
temperature, the ice maker
mechanism will fill the mold
with water.

Note: The first cubes may be
small because of air in the
water line. After two hours,
cubes will be standard size.

The ice maker will continue
to produce until the bin is
full. You may interrupt
production by raising the bin
arm into an upright and locked position (see Figure 27).
While the bin arm is locked, the unit will maintain
temperature for ice storage.

IMPORTANT

It is possible that dirt or scale will dislodge in the water
line. Always throw away all ice cubes made during the
first twenty-four (24) hours of operation.

10 Start-Up for the First Time