Installation – Vanguard Heating 000 to 26 User Manual

Page 14

Advertising
background image

www.desatech.com

113111-01A

14

INSTALLATION

Continued

Figure 16 - Removing Valve Cover Shield

1

2

Remove
Screw

Valve
Cover
Shield

Shoulder
Screw

Branch Support

Snap Bushings

Bottom Louver
Assembly

sembly to the outer casing with 4 #10 screws
provided (see Figure 17).

6.

Route the wire harness through the hole in left
side of baffle. Pull wire harness through lower
opening above where the valve shield was re-
moved. (see Figure 17).

7.

Insert the 4 wire harness into one of the round
holes in the rear of the valve cover shield and
through the rectangular hole in the front of
shield (see Figure 17).

8.

Reconnect red wire to switch position 3. Re-
connect blue wire to switch position 1. Re-
connect green and white wires.

9.

Install the switch plate on the valve cover
shield with 2 #10 screws provided (see Fig-
ure 17). Reinstall the valve cover shield. Route
power cord out of the cabinet by inserting it
through the bushing on the outer casing (see
Figure 17). Plug fan kit into 120-Volt
grounded power supply and test operation.

Note:

When switch is in the AUTO position,

the fan will start after the heater has run for a
few moments. The fan will continue to run
for several moments after the heater has been
turned off. When switch is in the ON posi-
tion, the fan will run until turned to OFF. Re-
install upper louver assembly and hood if pre-
viously removed, (see Figure 15, page 13).
Close lower louver door.

Installing Blower Assembly

CAUTION: Label all wires

prior to disconnection when ser-
vicing controls. Wiring errors
can cause improper and dan-
gerous operation.

CAUTION: Verify proper op-

eration after servicing.

Note:

If you are using a mantel with your heater,

use the following instructions. If your heater is
built-in, see For Built-In Installation on page 15.

1.

Install snap bushings found in hardware kit
into both holes in rear of valve cover shield.

2.

Make sure the wire harness is firmly con-
nected to the terminals on the blower bracket
assembly.

3.

Note the wire locations on back of AUTO/
OFF/ON switch. The terminals on back of
switch are numbered 1, 2, and 3. Carefully
remove red wire from terminal 1 and blue wire
from terminal 3. Black wire can remain on
middle terminal 2 (see Figure 17).

4.

Carefully disconnect green and white wires
at their insulated connectors.

5.

In top of the heater cabinet, locate the four
mounting holes on the outer casing. Align
these four holes with those on the blower
bracket assembly. Attach blower bracket as-

3
2
1

Figure 17 - Installing Blower Bracket

Assembly

Wire
Harness

Blower Bracket
Assembly

Screw

Valve Cover
Shield

Box Cover

Wire
Harness

Switch
Plate

Switch

Baffle

Wiring Routing
Hole in Baffle

Blue

Red

Power
Cord

Advertising
This manual is related to the following products:

000