of screen. Discard screws. Lift fireplace screen
up and pull out to remove.

2.

Remove screws that attach branch support to
fireplace (see Figure 24). Carefully lift up
branch support and remove from fireplace (see
Figure 24).

3.

Route flexible gas line included from fireplace
control to equipment shutoff valve through
side or rear access holes in outer casing.

NOTICE: Most building codes do
not permit concealed gas con-
nections. A flexible gas line is
provided to allow accessibility
from the fireplace (see Figure 24).
The flexible gas supply line con-
nection to the equipment shutoff
valve should be accessible.

CAUTION: Avoid damage to

regulator. Hold gas regulator
with wrench when connecting it
to gas piping and/or fittings.

4.

Apply pipe joint sealant lightly to male threads
of gas connector attached to flexible gas line/
equipment shutoff valve (see Figure 25, page 18).

5.

Check all gas connections for leaks. See
Checking Gas Connections, page 18.

6.

Replace branch support back into fireplace.
Feed flexible gas line into fireplace base area
while replacing branch support. Make sure the
entire flexible gas line is in fireplace base area.
Reattach branch support to fireplace with
screws removed in step 2.

INSTALLATION

Continued

Installation must include a equipment shutoff valve,
union, and plugged 1/8" NPT tap. Locate NPT tap
within reach for test gauge hook up. NPT tap must
be upstream from fireplace (see Figure 23).

IMPORTANT:

Install equipment shutoff valve in

an accessible location. The equipment shutoff
valve is for turning on or shutting off the gas to
the appliance.

Check your building codes for any special re-
quirements for locating equipment shutoff valve
to fireplaces.

Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from go-
ing into pipe. Excess sealant in pipe could result
in clogged fireplace valves.

WARNING: Use pipe joint

sealant that is resistant to liquid
petroleum (LP) gas.

Figure 23 - Gas Connection

CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*

PROPANE/LP
From External
Regulator (11" W.C.
to 14" W.C. Pressure)

NATURAL
From Gas Meter
(5" W.C. to
10.5" W.C.
Pressure)

3" Minimum

Pipe Cap

Tee

Nipple

Joint

Sediment Trap

* Purchase the optional CSA design-certified
equipment shutoff valve from your dealer. See
Accessories, page 30.

CONNECTING EQUIPMENT SHUTOFF
VALVE TO HEATER CONTROL

Installation Items Needed

• Phillips screwdriver

• sealant (resistant to propane/LP gas, not pro-

vided)

1.

To remove fireplace screen, remove two
screws that hold fireplace screen in place for
shipping. These screws are located near top

Figure 24 - Removing Log Base

Assembly From Fireplace

Branch
Support

Screen

Screen
Shipping
Screw

Shoulder
Screw

Flexible
Gas Line