INSTALLATION

NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your pri-
mary heat source. If you have a
central heating system, you may
run system’s circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

WARNING: A qualified ser-

vice person must install fire-
place. Follow all local codes.

WARNING: Never install the

fireplace
• in a bedroom or a bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the fireplace

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

CAUTION: This fireplace cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to fireplace. Install-
ing fireplace next to vinyl or cloth
wall coverings or operating fire-
place where impurities (such as,
but not limited to, tobacco
smoke, aromatic candles, clean-
ing fluids, oil or kerosene lamps,
etc.) in the air exist, may dis-
color walls or cause odors.

IMPORTANT:

Vent-free fireplaces add moisture

to the air. Although this is beneficial, installing
fireplace in rooms without enough ventilation air
may cause mildew to form from too much mois-
ture. See Air for Combustion and Ventilation, pages
6 through 8.

Note:

Your Vanguard fireplace is designed to be

used in zero clearance installations. Wall or fram-
ing material can be placed directly against any
exterior surface of your fireplace, except where
standoff spacers are integrally attached. If stand-
off spacers are attached to your fireplace, these
spacers can be placed directly against wall or fram-
ing materials.

Use the dimensions shown for rough openings to
create the easiest installation (see Built-In Fire-
place Installation
, page 10).

CHECK GAS TYPE

Use only the correct type of gas (natural or pro-
pane/LP). If your gas supply is not the correct gas
type, do not install heater. Call dealer where you
bought heater for proper type heater.

WARNING: This appliance

is equipped for (natural or pro-
pane/LP) gas. Field conversion
is not permitted.

INSTALLATION ITEMS

Before installing fireplace, make sure you have
the items listed below.

• external regulator - propane/LP only (supplied

by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• test gauge connection*

• ground joint union

• sediment trap

• tee joint

• pipe wrench

* A CSA design-certified equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. Purchase the optional CSA
design-certified equipment shutoff valve from your
dealer. See Accessories, page 30.

Note:

If desired, purchase a four-sided trim kit for

built-in installations. See Accessories, page 30.

Advertising