WARNING: If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT:

Operating fireplace where impurities in air exist may create odors. Cleaning supplies,

paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes.
These fumes may mix with combustion air and create odors.

POSSIBLE CAUSE

1. Fireplace burning vapors from

paint, hair spray, glues, etc.
(See

IMPORTANT

statement

above)

2. Low fuel supply (propane/LP)
3. Gas leak.

See Warning

statement above

1. Not enough fresh air is avail-

able

2. Low line pressure

3. ODS/pilot is partially clogged

1. Gas leak.

See Warning

statement above

2. Control valve defective

1. Foreign matter between con-

trol valve and burner

2. Gas leak.

See Warning

statement above

1. Not enough combustion/ven-

tilation air

REMEDY

1. Ventilate room. Stop using

odor causing products while
fireplace is running

2. Refill supply tank
3. Locate and correct all leaks

(see Checking Gas Connec-
tions
, page 18)

1. Open window and/or door for

ventilation

2. Contact local propane/LP or

natural gas company

3. Clean ODS/pilot (see Cleaning

and Maintenance, page 22)

1. Locate and correct all leaks

(see Checking Gas Connec-
tions
, page 18)

2. Replace control valve

1. Take apart gas tubing and re-

move foreign matter

2. Locate and correct all leaks

(see Checking Gas Connec-
tions
, page 18)

1. Refer to Air for Combustion

and Ventilation requirements
(page 6)

OBSERVED PROBLEM

Fireplace produces unwanted
odors

Fireplace shuts off in use (ODS
operates)

Gas odor even when control
knob is in OFF position

Gas odor during combustion

Moisture/condensation noticed
on windows