Troubleshooting – Vanguard Heating 000 to 26 User Manual

Page 24

Advertising
background image

www.desatech.com

113111-01A

24

POSSIBLE CAUSE

1. Control knob not fully

pressed in

2. Control knob not pressed in

long enough

3. Safety interlock system has

been triggered

4. Equipment shutoff valve not

fully open

5. Thermocouple connection

loose at control valve

6. Pilot flame not touching ther-

mocouple, which allows ther-
mocouple to cool, causing pi-
lot flame to go out. This prob-
lem could be caused by one or
both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot

7. Thermocouple damaged
8. Control valve damaged

1. Burner orifice is clogged

2. Inlet gas pressure is too low

1. Manifold pressure is too low

2. Burner orifice is clogged

1. Burner orifice is clogged or

damaged

2. Burner damaged
3. Low inlet gas pressure

4. Gas regulator defective

1. Not enough air

2. Gas regulator defective

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep

control knob pressed in 30
seconds

3. Wait one minute for safety in-

terlock system to reset. Repeat
ignition operation

4. Fully open equipment shutoff

valve

5. Hand tighten until snug, then

tighten 1/4 turn more

6. A) Contact local propane/LP

or natural gas company

B) Clean ODS/pilot (see
Cleaning and Maintenance,
page 22) or replace ODS/pi-
lot assembly

7. Replace pilot assembly
8. Replace control valve

1. Clean burner (see Cleaning

and Maintenance, page 22) or
replace burner orifice

2. Contact local propane/LP or

natural gas company

1. Contact local propane/LP or

natural gas company

2. Clean burner (see Cleaning

and Maintenance, page 22) or
replace burner orifice

1. Clean burner (see Cleaning

and Maintenance, page 22) or
replace burner orifice

2. Replace burner pressure
3. Contact local propane/LP or

natural gas company

4. Replace gas regulator

1. Check burner for dirt and de-

bris. If found, clean burner
(see Cleaning and Mainte-
nance
, page 22)

2. Replace gas regulator

OBSERVED PROBLEM

ODS/pilot lights but flame goes
out when control knob is re-
leased

Burner does not light after ODS/
pilot is lit

Delayed ignition of burner

Burner backfiring during com-
bustion

Yellow flame during burner
combustion

TROUBLESHOOTING

Continued

Advertising
This manual is related to the following products:

000