Owner’s manual, Installation, Continued – Vanguard Heating VMH26PRA User Manual

Page 11

Advertising
background image

11

107034

OWNER’S MANUAL

For more information, visit www.desatech.com

3
2
1

Continued

Figure 15 - Removing Upper Louver
Assembly and Branch Support

INSTALLATION

Continued

Blower Bracket
Mounting Holes

INSTALLING BLOWER
ACCESSORY GA3400T

Removing Upper Louver
Assembly

To install the blower accessory, you must
first remove the upper louver assembly.

1.

Lift screen off heater and remove log set.

2.

Remove 2 screws from each side of
branch support and pull branch support
out (see Figure 15).

3.

Remove 4 brass-plated screws from
louver assembly (see Figure 16). Save
these screws.

4.

Pull louver assembly straight out from
the cabinet. Be careful not to scratch
the paint. Set louver assembly and
screws aside.

Wire
Harness

Blower Bracket
Assembly

Screw

Power
Cord

Wire
Harness

Switch

Baffle

Wiring Routing
Hole in Baffle

Switch
Plate

Blue

Red

Installing Blower Assembly

Note:

If you are using a mantel with your

heater, use the following instructions. If
your heater is built-in, see For Built-In In-
stallation
on page 12.

1.

Install snap bushings found in hardware
kit into both holes in rear of valve cover
shield.

2.

Make sure the wire harness is firmly
connected to the terminals on the
blower bracket assembly.

Figure 16 - Installing Blower Bracket Assembly

Valve Cover
Shield

Snap
Bushing

Upper Louver
Assembly

Branch Support

CAUTION: Label all wires

prior to disconnection when ser-
vicing controls. Wiring errors
can cause improper and danger-
ous operation.

CAUTION: Verify proper

operation after servicing.

Side Brass
Trim

Top Brass Trim

Mitered Edge

Figure 14 - Assembling Brass Trim

Shim

Set
Screws

Adjusting

Plate

Slot

Slot

3.

Note the wire locations on back of
AUTO/OFF/ON switch. The terminals
on back of switch are numbered 1, 2,
and 3. Carefully remove red wire from
terminal 3 and blue wire from termi-
nal 1. Black wire can remain on middle
terminal 2 (see Figure 16).

4.

Carefully disconnect green and white
wires at their insulated connectors.

5.

In top of the heater cabinet, locate the
four mounting holes on the outer cas-
ing. Align these four holes with those
on the blower bracket assembly. Attach
blower bracket assembly to the outer
casing with 4 #10 screws provided (see
Figure 16).

6.

Route the wire harness through the hole
in left side of baffle. Pull wire harness
through lower opening on the side of
the valve shield. (see Figure 16).

7.

Insert the 4 wire harness into one of the
round holes in the rear of the valve cover
shield and through the rectangular hole
in the front of shield (see Figure 16).