Compact classic hearth fireplace vmh26pra, Installation, Continued – Vanguard Heating VMH26PRA User Manual

Page 16

Advertising
background image

16

107034

COMPACT CLASSIC HEARTH FIREPLACE

VMH26PRA

®

For more information, visit www.desatech.com

OPTIONAL WALL MOUNTED
THERMOSTAT - GWMT1

WARNING: Do not connect

this thermostat to any electrical
source! Electrical shock and/or
fire hazard will occur.

1.

Connect one terminal of 25 ft. wire to
bottom contact of switch (see Figure 33,
page 17).

2.

Connect remaining wire terminal to the
“TH” terminal on the control valve.
Make sure that wire terminals are in the
positions on your unit as pictured in
Figure 33 on page 17. If wires are not
“crossed” the thermostat will not work.

3.

Route the 25 ft. wire to a convenient
location to mount your thermostat (no
outside wall).

IMPORTANT:

The wire

may be shortened but must not be
lengthened.

The thermostat should be mounted 54"
above the floor in a location where there
is good air circulation. Avoid heat sources
such as lamps, direct sunlight, fireplace,
or heat and air conditioning ducts.

4.

Gently remove the cover of the ther-
mostat from the base. Grasp the sides
of the cover firmly and pull to separate
from the base.

5.

Feed the electrical wires through the
rectangular slots on each side of the
base (see Figure 34, page 17).

WARNING: Do not connect

the thermostat to a power source.
Electrical shock and/or a fire haz-
ard will occur.

WARNING: Read and follow

installation instructions. Instal-
lation should be done by a quali-
fied installer familiar with low-
voltage wiring procedures.

Figure 30 - Installing Remote Receiver

* Wire harness provided in the fireplace
hardware pack.

Installing 9-Volt Battery in Hand-
Held Remote Control Unit

1.

Remove battery cover on back of re-
mote control unit.

2. Attach terminal wires to the battery (not

included). Place battery into the battery
housing.

3.

Replace battery cover onto remote con-
trol unit.

Figure 31 - Installing Battery in Hand-
Held Remote Control Unit (GHRC Series)

Wires from
Valve

Wire Harness*

Black Wire

Red Wire

Red Wire

Black Wire

Battery
Cover

9-Volt
Battery

Terminal
Wires

Remote
Control Unit

Battery
Housing

Figure 32 - Installing Battery in Hand-Held
Remote Control Unit (GHRCTA Series)

Remote
Control
Unit

INSTALLATION

Continued

OPTIONAL WIRELESS HAND-
HELD REMOTE CONTROL
ACCESSORIES
(GHRC Series & GHRCTA
Series)

Installing Receiver

1.

Remove screws.

2.

Disconnect switch wires from the con-
trol valve.

3.

Remove switch plate (see Figure 28).
Discard switch plate after removing.
Save the screws.

4.

Locate the battery clip mounted on the
back of the receiver (see Figure 29).

5.

Slide 9-volt battery (not included)
through the clip.

6.

Attach the terminal wires to the battery
(see Figure 29).

7.

Connect wires as shown in Figure 30.

8.

Install remote receiver unit onto gas
heater base using the two screws re-
moved in step one (see Figure 30).

Figure 28 - Switch Plate and Wiring
Harness

Screw

Switch Plate

Black Wire

Red Wire

Figure 29 - Attaching Battery to Receiver

Battery Clip

9-Volt Battery

Receiver

Terminal
Wires