Owner’s manual, Technical service, Service hints – Vanguard Heating VMH26PRA User Manual

Page 25: Wiring diagram, Specifications, Replacement parts, Parts under warranty, Parts not under warranty

Advertising
background image

25

107034

OWNER’S MANUAL

For more information, visit www.desatech.com

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni-
cal Service Department at 1-800-323-5190.

You can also visit DESA International’s
technical services web site at

www.desatech.com.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply may be low

When Gas Quality Is Bad

• pilot will not stay lit

• burner will produce flames and soot

• fireplace will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.

WIRING DIAGRAM

Switch

Black

Auto

Off
On

Red

Red

White

Thermopile

Gas Control

TPTH

TH

TPTH TP

SPECIFICATIONS

Btu (Variable)

15,000/26,000

Type Gas

Propane/LP Only

Ignition

Piezo

Manifold Pressure

8" W.C.

Inlet Gas Pressure (in. of water) *

Maximum

14"

Minimum

11"

Dimensions, Inches (H x W x D)

Fireplace (including hood and screws)

25

7

/

8

x 26

13

/

16

x 9

3

/

8

Carton

32

5

/

8

x 27

3

/

16

x 11

5

/

8

Weight, pounds

Fireplace

44

1

/

2

lbs.

Shipping

48 lbs.

* For purposes of input adjustment

REPLACEMENT
PARTS

Note:

Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s) call DESA International’s Technical
Service Department at 1-800-323-5190 for
referral information.

When calling DESA International, have ready

• your name

• your address

• model and serial numbers of your fireplace

• how fireplace was malfunctioning

• type of gas used (propane/LP or natural

gas)

• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

PARTS NOT UNDER
WARRANTY

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s) call DESA International’s Parts De-
partment at 1-800-972-7879 for referral
information.

When calling DESA International, have ready

• model number of your fireplace

• the replacement part number

Advertising