Status leds – Vivotek IP3111/3121 User Manual

Page 11

Advertising
background image





10

www.vivotek.com

T:

886-2-22404099

F:

886-2-22404097






Status LEDs

Each time Network Camera starts, it will perform a Power-On Self Test, abbreviated as POST hereafter,

to examine every hardware module. As soon as the administrator plugs in the power adapter, both LEDs

under the network LED will flash one by one until the POST is done. If any module fails, both LEDs will

indicate to the users the error according to the pattern listed in Appendix A. If the result is good, both

LEDs will turn off for a while and then follows the pattern below. Network interface depends on the

peripherals including Ethernet UTP cable, modem or null modem cable. If the Ethernet cable between

Network Camera and Ethernet hub is good, Network Camera will choose the Ethernet network. If

Ethernet is unavailable but a operational modem is connected, the network interface will be PPP with

modem. If either of the above is not the case, Network Camera will try the interface of PPP with null

modem.

Network Interface

Condition

LED2 (Heartbeat)

LED3 (Status)

before installed

OFF

OFF

after installed

flash

OFF

Ethernet

during camera control

flash

Flash

PPP with modem

after POST

flash

ON

before connected

ON

ON

PPP with null modem

after connected

flash

ON

Advertising