Drive the digital output, Query status of the digital input – Vivotek PZ7131 User Manual

Page 118

Advertising
background image

VIVOTEK - A Leading Provider of Multimedia Communication Solutions

118 - User's Manual

1=>active

countryname

string[2]

6/6

country name in certificate information

stateorprovincena

me

string[128]

6/6

state or province name in in certificate

information

localityname

string[128]

6/6

the locality name in certificate information

organizationname

string[64]

6/6

organization naem in certificate information

unit

string[32]

6/6

organizational unit name in certificate information

commonname

string[64]

6/6

common name in certificate information

validdays

0 ~ 9999

6/6

certificatation valid period

Drive the digital output

Note: This request requires the privilege of viewer.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>]

[&do3=<state>][&do4=<state>][&return=<return page>]

Where state is 0, 1. “0” means inactive or normal state while “1” means active or triggered state.

PARAMETER

VALUE

DESCRIPTION

0 – inactive, normal state

do<num>

0, 1

1 – active, triggered state

return

<return page>

Redirect to the page <return page> after the parameter is

assigned. The <return page> can be a full URL path or relative

path according the the current path. If you omit this

parameter, it will redirect to an empty page.

Example: Drive the digital output 1 to triggered state and redirect to an empty page

http://myserver/cgi-bin/dido/setdo.cgi?do1=1

Query status of the digital input

Note: This request requires the privilege of viewer.

Method: GET/POST