Passthrough State: Responder

Passthrough State

Responder – In this case the VBrick will accept a connection request
(up to 64 connection requests).

Baud Rate

Rate of Passthrough port. Rate can be set to the following (Default
= 9600): 110, 300, 600, 1200, 2400, 3600, 4800, 7200, 9600, 14400,
19200, 28800, 38400, 57600, 115200.

Stop Bits

Number of stop bits for Passthrough port (1 or 2).

Parity

None, Even, Odd.

RTS Control

Force OFF, Force ON or Automatic. If automatic, the control will be
on when Passthrough is active. Under no conditions are RTS or
DTR controls passed through end-to-end. All control handling is
local. When using a VBrick VCC-3 or VCC-4 camera, set this control
to Automatic; when using a VBrick VCC-50i camera, set this control
to Force ON.

DTR Control

Force OFF, Force ON or Automatic. If automatic, the control will be
ON when Passthrough is active. Under no conditions are RTS or
DTR controls passed through end-to-end. All control handling is
local. When using a VBrick VCC-3 or VCC-4 camera, set this control
to Automatic; when using a VBrick VCC-50i camera, set this control
to Force ON.

COM Interface Type Describes the COM interface connector.

• RS232 – standard RS-232 serial port connector.
• RS422/485 – RS-422/485 4-wire serial port connector.

Advertising