Device tests, Trace route test result, Trace route test configuration – VBrick Systems 7000 User Manual

Page 71

Advertising
background image

Troubleshoot

VBrick H.264 Appliance Admin Guide

65

Trace Route Test Result

The results of the test appear at the top of the screen. The results include the

Resolved IP

Address

of the Destination Host Name. When the test is finished or stopped, the

Overall

Result

will display the result of the test, such as "Test Done," or "Max hops (=30) Finished,"

or "Test Stopped," etc. An entry shows the hop number, which is equal to the TTL, IP
address (and Host Name if available) of the gateway, and round trip time of each probe. If the
probe answers are received from different gateways, the address of each responding system
will be shown. If there is no response within a 5 second timeout interval, a "*" is printed for
that probe. If the result string exceeds 255 characters, the string will be terminated by ending
it with "Too Long."

Trace Route Test Configuration

Device Tests

The H.264 appliance automatically performs a full POST (Power On Self Test) hardware test
whenever the unit is powered-on or reset. The Device Test runs the POST and displays the
results. The

Operational Mode

(on the System Configuration > General page) must be set to

Diagnostics

to run this test. When done, be sure to reset the appliance to Run mode or you

will not be able to stream video.

T

To run the Device Test

1. Go to System Configuration > General and set the

Operational Mode

to

Diagnostics

.

2. Go back to the Device Tests page and click

Edit

.

3. Set the test parameters (see below).
4. Click

Start

and wait a few seconds to see the test results.

5. When done go back to System Configuration > General and set the

Operational Mode

to

Run

.

Resolved IP Address IP Address of destination.

Traceroute Result

Displays "done" when finished.

Summary

Shows results summary including byte packet size and number of
hops.

Destination

Select Host Name or unicast IP Address (multicast IP Addresses are
not valid).

Probe Count

Can be set from 3 to 20. The default setting is 3. This setting is the
number of probe packets sent to a host at each hop.