© 2009 VBrick Systems, Inc.

Table 3. Trap Summary

Authentication Password Enter password. Cannot exceed 20 characters. May include any

combination of alphanumeric characters but only the following
special characters:

~ ! # $ ^ * + & [ ] { } | < >

Authentication Protocol Select protocol: MD5 or SHA to validate the transaction

between a given host and client

Privacy Password

Required. Hides traffic using DES encryption.

Security Level

No Authentication, No Privacy (default).
No Privacy.
Authentication and Privacy.

Trap

Description

1

vbrickRemoteLog

Sent whenever a significant event occurs within
the VBrick. Each event provides details via the
vbrickSysRemoteEventLogType, and
vbrickSysRemoteEventLogText objects

2

vbrickSysTrapStartUpRunMode

Means the VBrick has started up in Run mode.

3

vbrickSysTrapStartUpDiagnosticsMode

The VBrick has started in Diagnostics mode.

4

vbrickSysTrapStartUpLimitedRunMode

Means the VBrick has started up in LimitedRun
mode.

5

vbrickSysTrapUserInitiatedReset

Means the VBrick has received a reset request
from an administrator.

6

vbrickSysTrapTemperatureOutOfRangeActive

Means the temperature of the VBrick is out of
range.

7

vbrickSysTrapTemperatureOutOfRangeCleared

Means the out of range VBrick temperature is
recovered.

8

vbrickSysTrapUnitOverloadedActive

Means the VBrick has been configured to
transmit and receive video streams beyond its
capability.

9

vbrickSysTrapUnitOverloadedCleared

Means the overloaded VBrick is recovered to
normal.

10

vbrickSysTrapPostFailure

Means that Power On Self Test (POST) failed.

11

vbrickSysTrapNetworkTimeProtocolServerDown

Means there is loss of connection to the
Network Time Protocol servers.

12

vbrickSysTrapNetworkTimeProtocolServerUp

Means there is a connection available now to the
Network Time Protocol servers.

13

vbrickSysTrapVideo1InputAlarmActive

Means that input #1 has a loss of video.

14

vbrickSysTrapVideo1InputAlarmClear

Means the loss of video on input #1 is
recovered.

15

vbrickSysTrapFanFailureActive

Means the fan failed.

16

vbrickSysTrapFanFailureCleared

Means the fan failure is recovered.

Advertising