VistaQuest N7227V5 User Manual

Page 36

Advertising
background image

– 36 –

10 Input S/N:

L

A002-4064 1

The system will enroll the serial number of the first transmitter heard,
add the loop number entered to this serial number, display the serial
and loop numbers, and cause the keypad to beep twice.

If the serial and loop number combination is already present in the
system, a single long beep will be heard from the keypad. If this happens,
the system will not display the serial number, but will wait for a
transmission from another transmitter or transmitter loop input.

12. The system will then enter an optional confirmation mode so that the

operation of the actual programmed input can be confirmed. Activate
the loop input or button that corresponds to this zone. We
recommend that you confirm the programming of every
transmitter before proceeding to the next zone.

10 Confirmed
A022– 4064 1

When the system sees activity on the appropriate input, it will beep
three times and display the confirmation message.

At any time during this step, you may press the [

] key on the keypad or

the upper left-hand button of the program tool if you are satisfied with the
serial and loop number combination that has been enrolled, regardless of
whether or not the enrolled input has been "confirmed."

If the incorrect transmitter has been enrolled, press the # key on the
keypad or the upper right-hand button of the program tool to delete the
serial number and return to the "Learn S/N" prompt. A single long beep will
be heard from the keypad to verify pressing of the upper right-hand button.
Then, press "1" (Yes) or press the upper left-hand button of the program
tool (a single short beep will verify the system is ready for enrolling) and
re-activate the proper transmitter or transmitter loop input.

ZN ZT – RC IN:

L

10

03

– 00

RF:

1 s

13. The summary screen for the zone will appear. Note that an "s"

indicates that a serial number has, in fact, been enrolled. The cursor
will be flashing above the loop number. Press [

] to accept the zone

information.
Note: If you entered “0” in step 10 previously, you will not get an
indication that the serial number has been enrolled.

If you want to delete the serial number, enter "0" and press [

]. The

system will then prompt, "Delete S/N?" Press the "1" (Yes) key to
complete the delete sequence. This process deletes the serial number
only,

not the loop number. The assumption is that the proper loop

number was programmed, but the wrong serial or loop number was
enrolled. To change the loop number, you must go back through zone
programming for that zone and manually enter the loop number over
the existing one.

Program Alpha?
0 = NO 1 = YES 0

14. If you want to program alpha descriptors now, enter "1" (Yes). See the

ALPHA DESCRIPTOR PROGRAMMING section for more information.
If not, enter "0" (No).

En te r Zn Nu m .

( 0 0 = Q UI T )

1 1

This will bring you back to the “Enter Zn Num.” prompt for the next
zone . When all zones have been programmed, enter “00” to quit.
If you plan to enroll serial numbers in the sequential enrollment mode,
enter “00” to quit, then go to

Section 13. SEQUENTIAL MODE section

later in this manual to enroll the serial numbers.

When you have finished programming all zones (including all serial
numbers), test each zone using the system's TEST mode. Do not use the
Transmitter ID Sniffer mode for this, as it will only check for transmission
of one zone on a particular transmitter, and NOT the zones assigned to
each additional loop.

Advertising